Professional-grade Sensor & Data System:

www.airzens.cloud

The Airzens sensor system is in compliance with ISO 14644-1 2015 cleanroom standard. The system is using laser scattering technologies for the accurate measurement of particles and related PID technologies for gaseous pollution.

Standard configuration: 

  • PM >0.3 µm number concentration
  • PM >0.5 µm number concentration
  • PM >1.0 µm number concentration
  • PM >2.5 µm number concentration
  • PM >5.0 µm number concentration
  • PM >10 µm number concentration
  • PM < 2.5 µm mass concentration

Optional configuration: 

  • PID TVOC sensor ( total volatile organic compounds)
  • CO2
  • Humidity
  • 03 ( ozone)
  • Temperature

The airzens.cloud solution makes it possible to monitor and manage the air quality in any building based on ISO 8 standards or other agreed standards of air quality.

Airzens sensor dashboard overview

Threshold settings

The thresholds for the desired air quality can be set in accordance with the agreed definitions and uploaded to www.airzens.cloud. Data and performance in relation to these set thresholds are available via the www.airzens.cloud dashboard. By setting these thresholds, specific standards for clean air are established, enabling tailored management of ventilation. Moreover, if these agreed limits are not met, an alarm can be triggered, either through a notification from www.airzens.cloud or via the building’s BMS (Building Management System) 

Threshold settings

The Airzens professional-grade sensor system goes beyond basic measurements, providing building managers with comprehensive data and analysis to optimize energy usage and ensure a safe environment for building occupants.

The sensor system utilizes state-of-the-art sensor technology to accurately measure multiple air quality parameters, both in the particle and gas phase. The Airzens system can measure ultrafine particles and a number of gases with precise measurements, as well as track energy and CO2 savings.

The Airzens library of professional-grade sensors offers flexibility and scalability to meet the specific needs of building managers. Whether the requirement is additional sensors to monitor specific parameters or expanding the system across multiple locations, a comprehensive range of sensor options is available.

This will enable building managers to gain a deeper understanding of their indoor environment and take proactive steps to improve air quality and energy usage.

 By continuously monitoring these metrics, building managers can identify opportunities for energy optimization and track the environmental impact of their building portfolio.

The Airzens system provides real-time data through www.airzens.cloud, allowing building managers to make informed decisions and implement strategies to reduce energy consumption and optimize air quality while minimizing carbon emissions.

Accessing the data collected by our sensor system is made easy through a dedicated dashboard. Building users and managers can securely log in and access the relevant data. The dashboard provides intuitive visualizations, analytics, and historical trends, enabling effective decision-making and proactive maintenance planning. Through the data interface, the system can manage ventilation based on multiple parameters, allowing building managers to customize and fine-tune the ventilation settings according to their preferences.

Sensor node for HVAC systems:

The Airzens nodes can be integrated into any ventilation system, extracting air samples directly from the duct via the inserted speer. The data is transmitted from the node to the cloud and can be linked to the building’s BMS system through a Modbus interface.

Clean room sensor system
Sensors installed
Sensor node

Airzens sensor

The Airzens Sensor Node is equipped with a sampling probe that can be inserted into a duct, enabling it to promptly sample and measure air quality. The sensor node is equipped with a modem and operates as an independent unit, transmitting air quality reports. The collected data is then uploaded to the www.airzens.cloud dashboard.

Monitoring energy and CO2 reductions  

Before and after upgrading a building’s ventilation to Airzens, you have the option to accurately assess energy usage and the resulting CO2 reductions.

Energy and environmental data can be tracked via www.airzens.cloud and/or integrate it into the building’s BMS system.

The Airzens energy sensor is a three-phase energy meter featuring a backlit LCD display and an integrated touch keypad. It is specifically designed for active energy measurement in applications up to 65 A (direct connection). This versatile meter can measure both imported and exported energy, offering additional features like pulse output, an RS485 Modbus port, and an M-bus port.

It is suitable for DIN-rail mounting and provides IP51 front-degree protection. For imported energy, optional legal metrology certification is available (PF option).

(Certified according to MID Directive, Module B and Module D of Annex II, for legal metrology relevant to active electrical energy meters (see Annex V, MI003, of MID). Can be used for fiscal (legal) metrology.)

[Picture: Installation at a hospital in the Copenhagen region]

Airzens sensor installation

Performance

Performance sensors air qquality